Menu
Panier 0
Techtop, GRA0034D-TC-01, 3 HP, 1760 Rpm, 230/460V, 182TC. Tefc, Premium

Techtop, GRA0034F-TC-01, 3 HP, 1760 Rpm, 575V, 182TC. Tefc, Premium

TECHTOP

  • $758.96


Techtop, GRA0034F-TC-01, Replace Maxmotion MPA-17, MPP-17, MPC-17W

  • HP 3
  • RPM 1760
  • Voltage 575
  • Phase 3
  • 60hz/ 50 Hz
  • Frame 182TC
  • Mounting Rigid/C-Flange
  • Enclosure TEFC
  • Material Cast Aluminum
  • Efficiency NEMA Premium
  • Rating IP 55 

STANDARD FEATURES

  • Removable feet F1, F2, F0 field convertible
  • 1.25 Service Factor with 60Hz operation / 1.0 Service Factor with 50Hz operation
  • 36 Month warranty
  • Conduit Box is 90º rotatable
  • Cast aluminum construction with cast aluminum c-flange and cast iron d-flange kits available
  • Compact lightweight design
  • CSA Certified for Class I, Division II, Groups A, B, C and D / Class I, Zone 2, Groups IIC, IIB, IIA
  • Anti-microbial (tropicalization) on stator winding
  • Shielded bearings
  • 1045 Steel shaft
  • Surface finish:
    • Alkyd enamel RAL7024 - Graphite Gray
    • Black oxide surface treatment for increased corrosion resistance
  • Stainless steel nameplate
  • Corrosion resistant hardware
  • Ultra high strength, reusable lifting straps included with motors 254T frame and larger

OPERATING PARAMETERS

  • Continuous (S1) duty
  • Ambient temperatures up to 40ºC
  • Installation up to 1000 MASL (3300 ft.)


CONNECTION

  • Up to and including 215T Frame:
  • 9-Lead 230V parallel-wye / 460V series-wye connection
  • 3-Lead 575V wye connection
  • 254T Frame and larger:
  • 12-Lead 230V parallel-delta / 460V delta connection
  • 6-Lead 460V or 575V single voltage delta connection


INGRESS PROTECTION

The standard degree of enclosure protection is IP55 (increased IP protection is available). Both drive end and non-drive end are fitted with double lip oil seals, including a rubber shaft slinger on the drive end. Terminal box is double gasketed. DE and NDE end bell fitted with sintered brass one-way drain.


INSULATION AND INVERTER RATING

  • Class F Insulation (Impregnation resin, magnet wire and insulation materials are Class H)
  • Designed to Class B temperature rise
  • Vacuum Impregnated
  • Inverter Rated 15:1 Constant Torque, 30:1 Variable Torque (1.0 S.F. on VFD Power)
  • Exceeds NEMA MG 1 Part 31.4.4.2

Nous vous recommandons également