{"product_id":"kbmm-si-6-signal-isolator-9444","title":"KBMM SI-6, Signal Isolator, P\/N 9444, KB Elec,Barrier Terminal Board Signal,","description":"\u003ch3 id=\"startDetails\" style=\"text-align: center;\"\u003e\u003cspan style=\"text-decoration: underline;\"\u003eKBMM SI-6 Signal Isolator, KB Electronics,\u003c\/span\u003e\u003c\/h3\u003e\n\u003cstyle type=\"text\/css\"\u003e\u003c!--td {border: 1px solid #cccccc;}br {mso-data-placement:same-cell;}--\u003e\u003c\/style\u003e\n\u003ctable xmlns=\"http:\/\/www.w3.org\/1999\/xhtml\" cellspacing=\"0\" cellpadding=\"0\" dir=\"ltr\" border=\"1\" style=\"table-layout: fixed; font-size: 10pt; font-family: Arial; width: 0px; border-collapse: collapse; border: none;\" data-sheets-root=\"1\" data-sheets-baot=\"1\"\u003e\n\u003ccolgroup\u003e\n\u003ccol width=\"188\"\u003e\n\u003ccol width=\"812\"\u003e\n\u003c\/colgroup\u003e\n\u003ctbody\u003e\n\u003ctr style=\"height: 21px;\"\u003e\n\u003ctd style=\"overflow: hidden; padding: 2px 3px 2px 3px; vertical-align: bottom; font-weight: bold; border: 1px solid #000000;\"\u003eSpecification\u003c\/td\u003e\n\u003ctd style=\"border-top: 1px solid #000000; border-right: 1px solid #000000; border-bottom: 1px solid #000000; overflow: hidden; padding: 2px 3px 2px 3px; vertical-align: bottom; font-weight: bold;\"\u003eDetails\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 21px;\"\u003e\n\u003ctd style=\"border-right: 1px solid #000000; border-bottom: 1px solid #000000; border-left: 1px solid #000000; overflow: hidden; padding: 2px 3px 2px 3px; vertical-align: bottom;\"\u003eModel Number\u003c\/td\u003e\n\u003ctd style=\"border-right: 1px solid #000000; border-bottom: 1px solid #000000; overflow: hidden; padding: 2px 3px 2px 3px; vertical-align: bottom;\"\u003eKBMM SI-6 Signal Isolator\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 21px;\"\u003e\n\u003ctd style=\"border-right: 1px solid #000000; border-bottom: 1px solid #000000; border-left: 1px solid #000000; overflow: hidden; padding: 2px 3px 2px 3px; vertical-align: bottom;\"\u003ePart Number\u003c\/td\u003e\n\u003ctd style=\"border-right: 1px solid #000000; border-bottom: 1px solid #000000; overflow: hidden; padding: 2px 3px 2px 3px; vertical-align: bottom;\"\u003e9444\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 21px;\"\u003e\n\u003ctd style=\"border-right: 1px solid #000000; border-bottom: 1px solid #000000; border-left: 1px solid #000000; overflow: hidden; padding: 2px 3px 2px 3px; vertical-align: bottom;\"\u003eCompatibility\u003c\/td\u003e\n\u003ctd style=\"border-right: 1px solid #000000; border-bottom: 1px solid #000000; overflow: hidden; padding: 2px 3px 2px 3px; vertical-align: bottom;\"\u003eDesigned for use with KBMM™ series DC motor speed controls\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 21px;\"\u003e\n\u003ctd style=\"border-right: 1px solid #000000; border-bottom: 1px solid #000000; border-left: 1px solid #000000; overflow: hidden; padding: 2px 3px 2px 3px; vertical-align: bottom;\"\u003eFunction\u003c\/td\u003e\n\u003ctd style=\"border-right: 1px solid #000000; border-bottom: 1px solid #000000; overflow: hidden; padding: 2px 3px 2px 3px; vertical-align: bottom;\"\u003eIsolates, amplifies, and conditions DC voltage and current signals from various sources\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 21px;\"\u003e\n\u003ctd style=\"border-right: 1px solid #000000; border-bottom: 1px solid #000000; border-left: 1px solid #000000; overflow: hidden; padding: 2px 3px 2px 3px; vertical-align: bottom;\"\u003eInput Signal Voltage\u003c\/td\u003e\n\u003ctd style=\"border-right: 1px solid #000000; border-bottom: 1px solid #000000; overflow: hidden; padding: 2px 3px 2px 3px; vertical-align: bottom;\"\u003eSelectable 0-5VDC or 0-10VDC via jumper J1; extendable to 0-100VDC or 0-200VDC with external resistors\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 21px;\"\u003e\n\u003ctd style=\"border-right: 1px solid #000000; border-bottom: 1px solid #000000; border-left: 1px solid #000000; overflow: hidden; padding: 2px 3px 2px 3px; vertical-align: bottom;\"\u003eInput Signal Current\u003c\/td\u003e\n\u003ctd style=\"border-right: 1px solid #000000; border-bottom: 1px solid #000000; overflow: hidden; padding: 2px 3px 2px 3px; vertical-align: bottom;\"\u003eSupports 4-20mA input with an external 270Ω resistor and J1 set to 5V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 21px;\"\u003e\n\u003ctd style=\"border-right: 1px solid #000000; border-bottom: 1px solid #000000; border-left: 1px solid #000000; overflow: hidden; padding: 2px 3px 2px 3px; vertical-align: bottom;\"\u003eOutput Voltage\u003c\/td\u003e\n\u003ctd style=\"border-right: 1px solid #000000; border-bottom: 1px solid #000000; overflow: hidden; padding: 2px 3px 2px 3px; vertical-align: bottom;\"\u003e0-10VDC, adjustable via built-in MIN and MAX trimpots\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 21px;\"\u003e\n\u003ctd style=\"border-right: 1px solid #000000; border-bottom: 1px solid #000000; border-left: 1px solid #000000; overflow: hidden; padding: 2px 3px 2px 3px; vertical-align: bottom;\"\u003ePower Requirements\u003c\/td\u003e\n\u003ctd style=\"border-right: 1px solid #000000; border-bottom: 1px solid #000000; overflow: hidden; padding: 2px 3px 2px 3px; vertical-align: bottom;\"\u003eOperates with 120 or 240VAC, selectable via jumpers J2A and J2B\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 21px;\"\u003e\n\u003ctd style=\"border-right: 1px solid #000000; border-bottom: 1px solid #000000; border-left: 1px solid #000000; overflow: hidden; padding: 2px 3px 2px 3px; vertical-align: bottom;\"\u003eFeatures\u003c\/td\u003e\n\u003ctd style=\"border-right: 1px solid #000000; border-bottom: 1px solid #000000; overflow: hidden; padding: 2px 3px 2px 3px; vertical-align: bottom;\"\u003eProvides an isolated +12VDC power supply for remote transducers or potentiometers; includes inhibit function for electronic start\/stop\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 21px;\"\u003e\n\u003ctd style=\"border-right: 1px solid #000000; border-bottom: 1px solid #000000; border-left: 1px solid #000000; overflow: hidden; padding: 2px 3px 2px 3px; vertical-align: bottom;\"\u003eInstallation\u003c\/td\u003e\n\u003ctd style=\"border-right: 1px solid #000000; border-bottom: 1px solid #000000; overflow: hidden; padding: 2px 3px 2px 3px; vertical-align: bottom;\"\u003eMates directly with KBMM™ controls via built-in quick-connect terminals\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 21px;\"\u003e\n\u003ctd style=\"border-right: 1px solid #000000; border-bottom: 1px solid #000000; border-left: 1px solid #000000; overflow: hidden; padding: 2px 3px 2px 3px; vertical-align: bottom;\"\u003eAdjustments\u003c\/td\u003e\n\u003ctd style=\"border-right: 1px solid #000000; border-bottom: 1px solid #000000; overflow: hidden; padding: 2px 3px 2px 3px; vertical-align: bottom;\"\u003eMIN and MAX trimpots for scaling output voltage; jumper settings for input signal range and AC line voltage\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 21px;\"\u003e\n\u003ctd style=\"border-right: 1px solid #000000; border-bottom: 1px solid #000000; border-left: 1px solid #000000; overflow: hidden; padding: 2px 3px 2px 3px; vertical-align: bottom;\"\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd style=\"border-right: 1px solid #000000; border-bottom: 1px solid #000000; overflow: hidden; padding: 2px 3px 2px 3px; vertical-align: bottom;\"\u003e0-50°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 21px;\"\u003e\n\u003ctd style=\"border-right: 1px solid #000000; border-bottom: 1px solid #000000; border-left: 1px solid #000000; overflow: hidden; padding: 2px 3px 2px 3px; vertical-align: bottom;\"\u003eManufacturer\u003c\/td\u003e\n\u003ctd style=\"border-right: 1px solid #000000; border-bottom: 1px solid #000000; overflow: hidden; padding: 2px 3px 2px 3px; vertical-align: bottom;\"\u003eKB Electronics\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003eThe Signal Isolators convert a standard control to an isolated input. By using external resistors, the input signal can be changed to\u003cbr\u003e0-100VDC, 0-200VDC and 4-20mA. The output voltage is 0-10VDC which can be rescaled with the built-in MIN and MAX trimpots.\u003cbr\u003eSelectable AC line jumpers allow the SI-5 to be used either with 115 or 208\/230 Volts AC controls. Installation is made by simply\u003cbr\u003emating the unit to the speed control with the built-in quick-connect terminals\u003cspan style=\"text-decoration: underline;\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca data-saferedirecturl=\"https:\/\/www.google.com\/url?q=https:\/\/acim.nidec.com\/drives\/kbelectronics\/-\/media\/kbelectronics\/documents\/dc-drives\/manuals\/si5_si6_manual.ashx?la%3De\u0026amp;source=gmail\u0026amp;ust=1722450579036000\u0026amp;usg=AOvVaw3M0DiXMfBH9jV_CMgFRRFC\" href=\"https:\/\/acim.nidec.com\/drives\/kbelectronics\/-\/media\/kbelectronics\/documents\/dc-drives\/manuals\/si5_si6_manual.ashx?la=e\" target=\"_blank\"\u003ehttps:\/\/acim.nidec.com\/drives\/\u003cwbr\u003ekbelectronics\/-\/media\/\u003cwbr\u003ekbelectronics\/documents\/dc-\u003cwbr\u003edrives\/manuals\/si5_si6_manual.\u003cwbr\u003eashx?la=e\u003c\/wbr\u003e\u003c\/wbr\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003c!----\u003e","brand":"KB ELECTRONIC","offers":[{"title":"Default Title","offer_id":48910797898032,"sku":"EMN-018202","price":172.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1512\/0768\/files\/9444_2024-07-30T18_39_58.372Z.png?v=1756412689","url":"https:\/\/www.emotornations.com\/en-us\/products\/kbmm-si-6-signal-isolator-9444","provider":"E-Motor Nations","version":"1.0","type":"link"}